APC NetShelter Rack PDU Advanced Gen 2 3-Phase 42 Outlet

0.0 · 0 reviews
$9,290.00
Pay now, in 4 interest-free payments of $2,322.50, or over 3–6 months
4 interest-free payments of $2,322.50

APC NetShelter Rack PDU Advanced Gen 2 delivers high-density, switched, metered power distribution with 42 versatile combo outlets for efficient rack deployment.Remote outlet control1% accurate power metering3-phase, up to 60A inputEcoStruxure IT int

13 in stock

↗
Estimated Delivery Time21 - 22 Nov 26

Efficient high-density power distribution

The APC NetShelter Rack PDU Advanced Gen 2 model enables reliable, metered power distribution to IT equipment inside server and networking racks. It offers 42 outlets in a slim 2.2-inch wide form factor to maximize rack space and equipment capacity.

Its outlets are color-coded and labeled by breaker for easier equipment management, supporting multiple outlet types for maximum deployment flexibility.

Flexible and precise power monitoring

Switched outlets provide remote control capabilities to turn individual outlets on or off, enhancing operational responsiveness. Power metering at both outlet and PDU levels enables detailed power usage analysis with 1% accuracy, helping with capacity planning and overload notifications.

  • Outlet and PDU level metering
  • 1% measurement accuracy
  • Power overload alerts

Advanced network and device management

This PDU integrates tightly with EcoStruxure IT via the NMC3 management card. It supports web, SNMP, and command line interface access. It includes a 1 Gbps Ethernet port and two link ports for cascading and network port sharing across up to 32 devices, simplifying network and power resource management.

  • NMC3 management card compatibility
  • Web, SNMP, CLI access
  • Cascade up to 32 PDUs using link ports

Robust physical and electrical design

Equipped with a 10-foot IEC-309 power cord (60 A, 3P+N+PE), it supports three-phase power at up to 60 A with 43.5 kW capacity at 400 V or 34.6 kW at 415 V. Rated for operation up to 60°C ensures reliability in high-density, heat-intensive environments.

  • 3-phase 60 A input
  • 10 ft power cord with IEC-309 connector
  • Operates up to 60°C (140°F)

Versatile outlet compatibility

The PDU's 4-in-1 combination outlets support C13, C15, C19, or C21 connectors, enabling connectivity with varied equipment plug types. This flexibility allows IT managers to deploy different rack equipment seamlessly without requiring additional adapters.

  • 21 combo C13/C15/C19/C21 outlets
  • 21 C13/C15 only outlets

Certified for global deployments

It holds multiple international certifications including UL, CE, CSA, UKCA, Nemko, PSE, KC, China RoHS, RCM, and CMIM, making it suitable for data centers worldwide where compliance is critical.

  • UL, CE, CSA certified
  • Complies with China RoHS and more

Optional environmental monitoring

Supports two environmental sensor ports for optional monitoring devices to track temperature, humidity, or other conditions, providing enhanced data center environment insight.

  • Two ports for external environmental sensors
  • Sensors sold separately

Key specifications

  • Maximum current: 60 A
  • Input voltage (Nominal): 415 V, 3 phases
  • Output voltage: 400 V / 240 V
  • Number of outlets: 42 (21 combo + 21 C13/C15)
  • Input connection: IEC-309 60 A 3P+N+PE
  • Cable length: 3 meters (10 feet)
  • Management platform: NMC3 with web, SNMP, CLI
  • Operating temperature: Up to 60°C (140°F)
  • Ethernet ports: One gigabit 10/100/1000 Mbps
  • Weight: 12.7 kg

What's in the box

  • APC NetShelter Rack PDU Advanced Gen 2 unit
  • 10 ft IEC-309 power cord (installed)
Product FAQ

Frequently asked questions

01 What type of outlets does the APC NetShelter Rack PDU Advanced Gen 2 have?

It features 42 outlets with 21 combo outlets supporting C13, C15, C19, or C21 plug types and 21 C13/C15 outlets.

02 Is remote control of outlets possible?

Yes, the PDU has switched outlets allowing remote on/off control.

03 What power metering capabilities does it have?

The PDU provides accurate outlet-level and overall power metering with 1% accuracy.

04 What input voltage and current ratings does it support?

It supports a nominal input voltage of 400-415 V at 3 phases and up to 60 A current.

05 How does the PDU integrate with network management?

It integrates with EcoStruxure IT via an NMC3 management card accessible through web, SNMP, or CLI interfaces.

06 What is the length of the input power cord?

The input power cord is 10 feet (3 meters) long with an IEC-309 60 A 3P+N+PE connector.

07 How many PDUs can be cascaded using the link ports?

Up to 32 PDUs can be cascaded using the two available link ports.

08 What environmental sensors are supported?

There are two ports available for optional environmental sensors, sold separately.

09 What certifications does this Rack PDU hold?

It is certified by UL, CE, CSA, UKCA, Nemko, PSE, KC, China RoHS, RCM, and CMIM.

10 What temperature can the PDU operate reliably at?

It is rated to operate reliably up to 60°C (140°F) at full load.